New One-Stage Factor VIII Assay Evaluated

By LabMedica International staff writers
Posted on 17 Mar 2022
Print article
Image: The cobas t 711 coagulation analyzer (Photo courtesy of Roche Diagnostics)
Image: The cobas t 711 coagulation analyzer (Photo courtesy of Roche Diagnostics)

Factor VIII (FVIII) is a multi-domain glycoprotein that is synthesized in the liver. As an essential blood coagulation protein required for normal hemostasis, FVIII circulates in plasma at normal concentrations of around 50–150 international units (IU)/dL in a non-covalent complex with von Willebrand factor.

FVIII is activated to factor VIIIa via limited proteolysis by thrombin and then acts as a cofactor to activated factor IX, during the activation of factor X to factor Xa, ultimately leading to clot formation. Deficiency of or dysfunctional FVIII leads to a bleeding diathesis of varying severity, depending on FVIII levels and/or activity.

Hematologists at the Sheffield Haemophilia and Thrombosis Centre (Sheffield, UK) and their international colleagues conducted a multicenter evaluation of a new one-stage factor VIII (FVIII) assay (Roche Diagnostics, Rotkreuz, Switzerland), intended for the quantitative assessment of FVIII activity. The team evaluated the analytical performance of the FVIII assay on a Roche analyzer.

Anonymized human 3.2% citrated plasma samples, both fresh and frozen to reflect routine laboratory practice, were used throughout the study. FVIII activity was assessed using the new one-stage FVIII assay on the cobas t 711 analyzer. Five human plasma pools and two controls were used to determine assay within-run and within-laboratory precision, and total reproducibility; coefficients of variation (CVs) and/or standard deviations (SDs) were calculated. Lot-to-lot variability and method comparison versus Coagulation FVIII Deficient Plasma/Dade Actin FS Activated PTT reagent/Standard Human Plasma Calibrator on the Sysmex CS-5100 analyzer (Milton Keynes, UK) and were evaluated by Passing–Bablok and Deming regression, respectively, and Pearson's r calculated. Assay-specific reference range was determined using 199 fresh plasma samples from healthy adults, not receiving anticoagulants.

The investigators reported that the method comparisons were conducted at three international sites across the primary measuring range of both the new one-stage FVIII assay on the cobas t 711 analyzer and reference comparator assay on the Sysmex CS-5100 analyzer. Good agreement between the new one-stage FVIII assay and comparator assay was observed at three different sites. Among apparently healthy individuals, FVIII activity ranged from 82.2 to 218.0 IU/dL in fresh samples and from 79.8 to 211.0 IU/dL in frozen samples.

The authors concluded that the new one-stage FVIII assay demonstrated robust analytical performance on the cobas t 711 analyzer, supporting its use in routine laboratory practice. The study was published on March 11, 2022 in the Journal of Clinical Laboratory Analysis.

Related Links:
Sheffield Haemophilia and Thrombosis Centre 
Roche Diagnostics 
Sysmex 

Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Parainfluenza Virus Test
PARAINFLUENZA ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more