Biomarker Protein Investigated in Juvenile Idiopathic Arthritis
By LabMedica International staff writers Posted on 09 Mar 2021 |

Image: An enzyme-linked immunosorbent assay (ELISA) measured serum 14–3-3η levels and evaluated in juvenile idiopathic arthritis (Photo courtesy of Quest Diagnostics).
Juvenile idiopathic arthritis (JIA) is the most common pediatric rheumatologic disease that may persist into adulthood and impact quality of life. The diagnosis is mainly based on clinical assessment rather than relying on laboratory testing.
The disease course and prognosis of JIA may vary based on multiple factors such as presence of the biomarkers rheumatoid factor (RF) and cyclic citrullinated peptide (CCP) antibodies. RF-seropositive polyarticular JIA (PJIA RF+) has similar features as adult rheumatoid arthritis (RA) and may extend into adulthood. The biomarker 14–3-3η is highly sensitive and specific for RA in adults.
Rheumatologists and their colleagues at the Children's Hospital of Los Angeles (Los Angeles, CA, USA) recruited 151 JIA patients who were categorized into five groups: polyarticular JIA RF+ (PJIA RF+; n = 39), PJIA RF- (n = 39), psoriatic arthritis (PsA; n = 19), enthesitis-related arthritis (ERA; n = 18), and oligoarticular JIA (OJIA [control group]; n = 36). Laboratory studies, including erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP), were obtained at the same time.
Specimens for CCP antibody, RF, antinuclear antibody (ANA), and HLA-B27 testing were also obtained. Samples for 14–3-3η were centrifuged and the serum was collected. Serum was stored in a freezer and sent to Quest Diagnostics Nichols Institute (San Juan Capistrano, CA, USA) overnight. 14–3-3η was measured via enzyme-linked immunosorbent assay (ELISA) at Quest Diagnostics. A 14–3-3η serum level of > 0.2 ng/mL was considered positive.
The team reported that elevated 14-3-3η levels were detected in 34/151 (23%) patients, and across all groups tested. Most patients with 14-3-3η had titers ≥4 times above the cutoff value. The majority (22, 65%) of 14-3-3η-positive patients were also positive for RF or CCP antibodies, 16 (47%) were positive for all three, and 12 (35%) were single-positive for 14-3-3η. The highest prevalence of 14-3-3η was in PJIA RF+ patients (49%), followed by OJIA (22%). Positivity for 14-3-3η was not significantly associated with disease activity or age at diagnosis.
The authors concluded that serum 14-3-3η can be detected in all forms of JIA tested, but appears to be most common in PJIA RF+. However, 14-3-3η does not appear to correlate with disease activity in JIA. The study was published on February 16, 2021 in the journal Pediatric Rheumatology.
Related Links:
Children's Hospital of Los Angeles
Quest Diagnostics
The disease course and prognosis of JIA may vary based on multiple factors such as presence of the biomarkers rheumatoid factor (RF) and cyclic citrullinated peptide (CCP) antibodies. RF-seropositive polyarticular JIA (PJIA RF+) has similar features as adult rheumatoid arthritis (RA) and may extend into adulthood. The biomarker 14–3-3η is highly sensitive and specific for RA in adults.
Rheumatologists and their colleagues at the Children's Hospital of Los Angeles (Los Angeles, CA, USA) recruited 151 JIA patients who were categorized into five groups: polyarticular JIA RF+ (PJIA RF+; n = 39), PJIA RF- (n = 39), psoriatic arthritis (PsA; n = 19), enthesitis-related arthritis (ERA; n = 18), and oligoarticular JIA (OJIA [control group]; n = 36). Laboratory studies, including erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP), were obtained at the same time.
Specimens for CCP antibody, RF, antinuclear antibody (ANA), and HLA-B27 testing were also obtained. Samples for 14–3-3η were centrifuged and the serum was collected. Serum was stored in a freezer and sent to Quest Diagnostics Nichols Institute (San Juan Capistrano, CA, USA) overnight. 14–3-3η was measured via enzyme-linked immunosorbent assay (ELISA) at Quest Diagnostics. A 14–3-3η serum level of > 0.2 ng/mL was considered positive.
The team reported that elevated 14-3-3η levels were detected in 34/151 (23%) patients, and across all groups tested. Most patients with 14-3-3η had titers ≥4 times above the cutoff value. The majority (22, 65%) of 14-3-3η-positive patients were also positive for RF or CCP antibodies, 16 (47%) were positive for all three, and 12 (35%) were single-positive for 14-3-3η. The highest prevalence of 14-3-3η was in PJIA RF+ patients (49%), followed by OJIA (22%). Positivity for 14-3-3η was not significantly associated with disease activity or age at diagnosis.
The authors concluded that serum 14-3-3η can be detected in all forms of JIA tested, but appears to be most common in PJIA RF+. However, 14-3-3η does not appear to correlate with disease activity in JIA. The study was published on February 16, 2021 in the journal Pediatric Rheumatology.
Related Links:
Children's Hospital of Los Angeles
Quest Diagnostics
Latest Clinical Chem. News
- 3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models
- POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection
- Highly Reliable Cell-Based Assay Enables Accurate Diagnosis of Endocrine Diseases
- New Blood Testing Method Detects Potent Opioids in Under Three Minutes
- Wireless Hepatitis B Test Kit Completes Screening and Data Collection in One Step
- Pain-Free, Low-Cost, Sensitive, Radiation-Free Device Detects Breast Cancer in Urine
- Spit Test Detects Breast Cancer in Five Seconds
- Electrochemical Sensors with Next-Generation Coating Advances Precision Diagnostics at POC
- First-Of-Its-Kind Handheld Device Accurately Detects Fentanyl in Urine within Seconds
- New Fluorescent Sensor Array Lights up Alzheimer’s-Related Proteins for Earlier Detection
- Automated Mass Spectrometry-Based Clinical Analyzer Could Transform Lab Testing
- Highly Sensitive pH Sensor to Aid Detection of Cancers and Vector-Borne Viruses
- Non-Invasive Sensor Monitors Changes in Saliva Compositions to Rapidly Diagnose Diabetes
- Breakthrough Immunoassays to Aid in Risk Assessment of Preeclampsia
- Urine Test for Monitoring Changes in Kidney Health Markers Can Predict New-Onset Heart Failure
- AACC Releases Comprehensive Diabetes Testing Guidelines
Channels
Molecular Diagnostics
view channel
Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset
Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more
Blood Test Could Detect HPV-Associated Cancers 10 Years before Clinical Diagnosis
Human papilloma virus (HPV) is known to cause various cancers, including those of the genitals, anus, mouth, throat, and cervix. HPV-associated oropharyngeal cancer (HPV+OPSCC) is the most common HPV-associated... Read moreHematology
view channel
Next Generation Instrument Screens for Hemoglobin Disorders in Newborns
Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more
First 4-in-1 Nucleic Acid Test for Arbovirus Screening to Reduce Risk of Transfusion-Transmitted Infections
Arboviruses represent an emerging global health threat, exacerbated by climate change and increased international travel that is facilitating their spread across new regions. Chikungunya, dengue, West... Read more
POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy
Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more
First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy
Hemoglobin disorders rank as some of the most prevalent monogenic diseases globally. Among various hemoglobin disorders, beta thalassemia, a hereditary blood disorder, affects about 1.5% of the world's... Read moreImmunology
view channel
Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies
Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more
AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell
Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more
Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment
Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read moreMicrobiology
view channel
Mouth Bacteria Test Could Predict Colon Cancer Progression
Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more.jpg)
Unique Metabolic Signature Could Enable Sepsis Diagnosis within One Hour of Blood Collection
Sepsis is a life-threatening condition triggered by an extreme response of the body to an infection. It requires immediate medical intervention to prevent potential death or lasting damage.... Read morePathology
view channel
Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse
High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more.jpg)
Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection
Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read moreTechnology
view channel
New Diagnostic System Achieves PCR Testing Accuracy
While PCR tests are the gold standard of accuracy for virology testing, they come with limitations such as complexity, the need for skilled lab operators, and longer result times. They also require complex... Read more
DNA Biosensor Enables Early Diagnosis of Cervical Cancer
Molybdenum disulfide (MoS2), recognized for its potential to form two-dimensional nanosheets like graphene, is a material that's increasingly catching the eye of the scientific community.... Read more
Self-Heating Microfluidic Devices Can Detect Diseases in Tiny Blood or Fluid Samples
Microfluidics, which are miniature devices that control the flow of liquids and facilitate chemical reactions, play a key role in disease detection from small samples of blood or other fluids.... Read more
Breakthrough in Diagnostic Technology Could Make On-The-Spot Testing Widely Accessible
Home testing gained significant importance during the COVID-19 pandemic, yet the availability of rapid tests is limited, and most of them can only drive one liquid across the strip, leading to continued... Read moreIndustry
view channel
ECCMID Congress Name Changes to ESCMID Global
Over the last few years, the European Society of Clinical Microbiology and Infectious Diseases (ESCMID, Basel, Switzerland) has evolved remarkably. The society is now stronger and broader than ever before... Read more
Bosch and Randox Partner to Make Strategic Investment in Vivalytic Analysis Platform
Given the presence of so many diseases, determining whether a patient is presenting the symptoms of a simple cold, the flu, or something as severe as life-threatening meningitis is usually only possible... Read more