Three Automated Urine Analyzers Compared with Manual Microscopic Urinalysis
By LabMedica International staff writers Posted on 03 Mar 2021 |

Image: The iRICELL series combines urine chemistry and microscopy in a fully automated, walk-away workcell that is easy to use and maintain and optimizes and advances urinalysis and body fluid testing (Photo courtesy of Beckman Coulter).
Urinalysis is an essential screening test in clinical laboratories in order to diagnose and plan treatment for urinary tract infections, kidney disease and diabetes. Urinalysis includes visual examination, evaluation of chemical parameters and microscopic examination.
Microscopic examination is fundamental to urine analysis. This is a simple way to collect informative data, but it is also labor-intensive, time-consuming, and requires experienced staff for accurate results and interpretation. Several automated urine analyzers have been introduced for urine analysis in medical laboratories.
Clinical Medical Laboratorians at the Prince of Songkla University (Songkhla, Thailand) collected fresh 100 urine samples in preservative-free containers and transferred to four different test tubes for three automated urine analyzers without centrifuging and manual microscopy by three experienced medical technologists, independently using the same microscope slide.
The scientists assessed and compared the performance of the most common three automated urine analyzers: Cobas 6500 (Roche Diagnostics, Indianapolis, IN, USA); UN3000-111b (Sysmex Corporation, Kobe, Japan); and iRICELL 3000 (Beckman Coulter, Brea, CA, USA). The Cobas 6500 is a combination of two analyzers including the Cobas u601 which analyzes physical and chemical components, and the Cobas u701 which performs microscopic examinations. The UN3000-111b has two component analyzers in a single platform including a chemical component (UC-3500 analyzer) for analyzing the physical and chemical parts of urine and a fluorescence flow cytometry component (UF-5000 analyzer) for microscopic examination of sediments. The iRICELL 3000 is a combination of two component analyzers including a chemical component (iChemVELOCITY) and a microscopic examination component (iQ200).
The medical laboratorians reported that there was good correlation of urine physical and chemical analyses between the three analyzers with an overall concordance level of more than 80%. For sediment analysis, the degree of concordance between manual analysis and the three instruments was very good to good for white blood cells, red blood cells and epithelial cells, and moderate for bacteria. There were fair to good agreements between manual microscopy and the three instruments, Cobas 6500, UN3000-111b and iRICELL 3000, for casts (Cohen’s kappa 0.42, 0.38 and 0.62, respectively).
The authors concluded that the three automated urine analyzers showed similar performances and good correlation with manual microscopy. The results of this study indicate that automated urine analyzers could be used for initial urine testing to reduce high workloads and to save time, but manual microscopic analysis by experienced staff is still necessary to classify urine sediments for confirmation, especially in pathologic specimens. The study was published in the March, 2021 issue of the journal Practical Laboratory Medicine.
Related Links:
Prince of Songkla University
Roche Diagnostics
Sysmex Corporation
Beckman Coulter
Microscopic examination is fundamental to urine analysis. This is a simple way to collect informative data, but it is also labor-intensive, time-consuming, and requires experienced staff for accurate results and interpretation. Several automated urine analyzers have been introduced for urine analysis in medical laboratories.
Clinical Medical Laboratorians at the Prince of Songkla University (Songkhla, Thailand) collected fresh 100 urine samples in preservative-free containers and transferred to four different test tubes for three automated urine analyzers without centrifuging and manual microscopy by three experienced medical technologists, independently using the same microscope slide.
The scientists assessed and compared the performance of the most common three automated urine analyzers: Cobas 6500 (Roche Diagnostics, Indianapolis, IN, USA); UN3000-111b (Sysmex Corporation, Kobe, Japan); and iRICELL 3000 (Beckman Coulter, Brea, CA, USA). The Cobas 6500 is a combination of two analyzers including the Cobas u601 which analyzes physical and chemical components, and the Cobas u701 which performs microscopic examinations. The UN3000-111b has two component analyzers in a single platform including a chemical component (UC-3500 analyzer) for analyzing the physical and chemical parts of urine and a fluorescence flow cytometry component (UF-5000 analyzer) for microscopic examination of sediments. The iRICELL 3000 is a combination of two component analyzers including a chemical component (iChemVELOCITY) and a microscopic examination component (iQ200).
The medical laboratorians reported that there was good correlation of urine physical and chemical analyses between the three analyzers with an overall concordance level of more than 80%. For sediment analysis, the degree of concordance between manual analysis and the three instruments was very good to good for white blood cells, red blood cells and epithelial cells, and moderate for bacteria. There were fair to good agreements between manual microscopy and the three instruments, Cobas 6500, UN3000-111b and iRICELL 3000, for casts (Cohen’s kappa 0.42, 0.38 and 0.62, respectively).
The authors concluded that the three automated urine analyzers showed similar performances and good correlation with manual microscopy. The results of this study indicate that automated urine analyzers could be used for initial urine testing to reduce high workloads and to save time, but manual microscopic analysis by experienced staff is still necessary to classify urine sediments for confirmation, especially in pathologic specimens. The study was published in the March, 2021 issue of the journal Practical Laboratory Medicine.
Related Links:
Prince of Songkla University
Roche Diagnostics
Sysmex Corporation
Beckman Coulter
Latest Clinical Chem. News
- 3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models
- POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection
- Highly Reliable Cell-Based Assay Enables Accurate Diagnosis of Endocrine Diseases
- New Blood Testing Method Detects Potent Opioids in Under Three Minutes
- Wireless Hepatitis B Test Kit Completes Screening and Data Collection in One Step
- Pain-Free, Low-Cost, Sensitive, Radiation-Free Device Detects Breast Cancer in Urine
- Spit Test Detects Breast Cancer in Five Seconds
- Electrochemical Sensors with Next-Generation Coating Advances Precision Diagnostics at POC
- First-Of-Its-Kind Handheld Device Accurately Detects Fentanyl in Urine within Seconds
- New Fluorescent Sensor Array Lights up Alzheimer’s-Related Proteins for Earlier Detection
- Automated Mass Spectrometry-Based Clinical Analyzer Could Transform Lab Testing
- Highly Sensitive pH Sensor to Aid Detection of Cancers and Vector-Borne Viruses
- Non-Invasive Sensor Monitors Changes in Saliva Compositions to Rapidly Diagnose Diabetes
- Breakthrough Immunoassays to Aid in Risk Assessment of Preeclampsia
- Urine Test for Monitoring Changes in Kidney Health Markers Can Predict New-Onset Heart Failure
- AACC Releases Comprehensive Diabetes Testing Guidelines
Channels
Molecular Diagnostics
view channel
Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset
Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more
Blood Test Could Detect HPV-Associated Cancers 10 Years before Clinical Diagnosis
Human papilloma virus (HPV) is known to cause various cancers, including those of the genitals, anus, mouth, throat, and cervix. HPV-associated oropharyngeal cancer (HPV+OPSCC) is the most common HPV-associated... Read moreHematology
view channel
Next Generation Instrument Screens for Hemoglobin Disorders in Newborns
Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more
First 4-in-1 Nucleic Acid Test for Arbovirus Screening to Reduce Risk of Transfusion-Transmitted Infections
Arboviruses represent an emerging global health threat, exacerbated by climate change and increased international travel that is facilitating their spread across new regions. Chikungunya, dengue, West... Read more
POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy
Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more
First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy
Hemoglobin disorders rank as some of the most prevalent monogenic diseases globally. Among various hemoglobin disorders, beta thalassemia, a hereditary blood disorder, affects about 1.5% of the world's... Read moreImmunology
view channel
Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies
Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more
AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell
Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more
Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment
Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read moreMicrobiology
view channel
Mouth Bacteria Test Could Predict Colon Cancer Progression
Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more.jpg)
Unique Metabolic Signature Could Enable Sepsis Diagnosis within One Hour of Blood Collection
Sepsis is a life-threatening condition triggered by an extreme response of the body to an infection. It requires immediate medical intervention to prevent potential death or lasting damage.... Read morePathology
view channel
Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse
High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more.jpg)
Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection
Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read moreTechnology
view channel
New Diagnostic System Achieves PCR Testing Accuracy
While PCR tests are the gold standard of accuracy for virology testing, they come with limitations such as complexity, the need for skilled lab operators, and longer result times. They also require complex... Read more
DNA Biosensor Enables Early Diagnosis of Cervical Cancer
Molybdenum disulfide (MoS2), recognized for its potential to form two-dimensional nanosheets like graphene, is a material that's increasingly catching the eye of the scientific community.... Read more
Self-Heating Microfluidic Devices Can Detect Diseases in Tiny Blood or Fluid Samples
Microfluidics, which are miniature devices that control the flow of liquids and facilitate chemical reactions, play a key role in disease detection from small samples of blood or other fluids.... Read more
Breakthrough in Diagnostic Technology Could Make On-The-Spot Testing Widely Accessible
Home testing gained significant importance during the COVID-19 pandemic, yet the availability of rapid tests is limited, and most of them can only drive one liquid across the strip, leading to continued... Read moreIndustry
view channel
ECCMID Congress Name Changes to ESCMID Global
Over the last few years, the European Society of Clinical Microbiology and Infectious Diseases (ESCMID, Basel, Switzerland) has evolved remarkably. The society is now stronger and broader than ever before... Read more
Bosch and Randox Partner to Make Strategic Investment in Vivalytic Analysis Platform
Given the presence of so many diseases, determining whether a patient is presenting the symptoms of a simple cold, the flu, or something as severe as life-threatening meningitis is usually only possible... Read more